Common Misconceptions in Installing Vertical Multistage Centrifugal Pumps
Product News

Common Misconceptions in Installing Vertical Multistage Centrifugal Pumps

2026-08-28

Common Misconceptions in Installing Vertical Multi-stage centrifugal pumps

During the installation of vertical multistage centrifugal pumps, even minor oversights can lead to improper installation, affecting the pump's operational performance. Below is an analysis of common installation pitfalls and corresponding solutions for vertical multistage centrifugal pumps.

1. There are numerous elbows in the suction pipeline of the vertical multistage centrifugal pump
If too many elbows are used in the inlet pipeline, it will increase some flow resistance. Additionally, elbows should bend in the vertical direction and are not allowed to bend horizontally to prevent air accumulation.

2. When installing the inlet pipeline of the device, ensure the horizontal section is level or slightly upward
This method will cause air to accumulate in the water pipe, reducing the vacuum level of the water pipe and Pump, thereby decreasing the Pump's suction lift and water output. The correct approach is to slightly slope the horizontal section toward the water source; it should not be level, nor should it arch upward.

3. The suction inlet of the multistage centrifugal pump is directly connected to the elbow
This will cause uneven distribution of water flow when it passes through the elbow and enters the impeller. When the diameter of the inlet pipe is larger than the Pump's suction port, an eccentric reducer should be installed, with some parts mounted above and others below. Otherwise, air accumulation may occur, leading to reduced water output, inability to draw water, and impact noises. If the diameters of the inlet pipe and the Pump's suction port are equal, a straight pipe should be added between the Pump's suction port and the elbow, with the straight pipe length not less than 2 to 3 times the diameter of the pipe.

4. The outlet pipe of the multistage centrifugal pump is positioned above the normal water level of the discharge pool
If the outlet is above the normal water level of the outlet pool, although the pump head is increased, the flow rate will be reduced. If the terrain conditions necessitate that the outlet be higher than the water level of the outlet pool, a bend and short pipe should be installed at the pipe outlet to convert the pipeline into a siphonic type.

5. The direction of the inlet for the feed pipe is incorrect
The distance between the inlet of the water inlet pipe and the bottom or wall of the water pool should be less than the diameter of the inlet. If there are mud or debris on the pool bottom, when the distance between the inlet and the pool bottom is less than 1.5 times the diameter, it may result in poor water intake or the suction of mud and debris, leading to blockage of the inlet.
② When the water intake depth of the inlet pipe is insufficient, it can cause vortices around the pipe, affecting water intake and reducing the flow rate.

6. When installing a bottom valve, the lowest section of the inlet pipe is not straight
For such installations, the valve cannot seal itself, leading to water leakage. The correct installation method is: the lowermost section of the inlet pipe with a foot valve should be vertical.