Leave Your Message
Key Points for Pump Unit Selection and Installation
Product News

Key Points for Pump Unit Selection and Installation

2026-09-07

Key Points for Pump Unit Selection and Installation

The Pump unit is the primary equipment for Pump station operations, consisting of the Pump, power unit, and transmission devices, also known as the main unit. Auxiliary equipment, electrical devices, and various structures in the Pump station serve the operation and maintenance of the main unit.

1. Selection of Pump Units
The core of Pump unit selection lies in the selection of the Pump itself, followed by determining the power unit model and other supporting equipment based on the Pump selection.
The most commonly used type in pump station projects is the impeller pump, which transfers energy to the liquid through the rotation of the impeller. It is divided into centrifugal pumps, axial flow pumps, and mixed flow pumps. Pumps are categorized by the installation form of the pump shaft into vertical, horizontal, and inclined types. The specific speed is a comprehensive characteristic number that reflects the commonality of impeller pumps, serving as the foundation for pump standardization and a universal similarity criterion.

centrifugal pump
Classification by inlet direction: single suction, double suction
By the number of impellers: single-stage (one impeller) and multi-stage (two or more impellers)

The structural forms of Water Pumps are divided into vertical and horizontal types, with their characteristics and applicable conditions as follows:
Vertical pump: The impeller is submerged underwater, making it easy to start. The motor is installed on the upper layer, facilitating flood prevention and ventilation. The plant hall has a relatively high height, requires high installation accuracy, and involves troublesome maintenance. It is suitable for locations with significant fluctuations in water levels.

Horizontal pumps: Lower installation accuracy than vertical pumps, lower risk of counterfeiting, easy for maintenance, require water flushing and air venting before startup, larger footprint in pump rooms, more uniform load distribution. Suitable for locations with lower foundation bearing capacity and relatively stable water level fluctuations.

Installation Technical Requirements
Before installation, obtain the equipment installation drawings, architectural structural drawings, manufacturer-provided assembly drawings and manuals, foundation acceptance documents, benchmark lines, and elevation points. Conduct a thorough cleaning and inspection of the equipment, and verify the fit dimensions and tolerances.

Summary
The selection of pump units should be based on engineering conditions such as head, flow rate, and water level fluctuation, with centrifugal pumps chosen appropriately. Key control points including joint precision, pressure resistance, coating standards, and on-site conditions must be strictly managed to ensure the installation quality of the units meets standards.