Leave Your Message
Reasons for the drop in outlet pressure of a vertical multistage centrifugal pump (booster pump)
Product News

Reasons for the drop in outlet pressure of a vertical multistage centrifugal pump (booster pump)

2026-09-14

Reasons for Decreased Outlet Pressure in Vertical Multistage centrifugal pumps (Booster Pumps)

There are many reasons why the outlet pressure of a stainless steel vertical multistage centrifugal pump might drop. Once we understand these reasons, we can take corresponding actions based on the actual situation on-site to fix the issues with the vertical stainless steel multistage pump.

Specifically, the reasons include the following (if anything is missing, feel free to add):

1. Motor running in the wrong direction
Due to wiring issues, the motor might rotate in the opposite direction than required by the Pump. Usually, when starting, you should jog the motor a bit to check if the Pump's rotation matches the required direction. If it’s reversed, just swap any two wires on the motor terminal, and it should fix the issue.

2. Internal leakage in the centrifugal pump
If the gaps between the rotating and stationary parts exceed the design range, internal leakage will occur, manifesting as decreased Pump outlet pressure, such as clearances at the impeller eye or between stages in a multistage Pump. In this case, the Pump should be disassembled and inspected, and parts with excessive clearances should be repaired or replaced.

3. Reduced Pump speed
An important factor affecting pump head is the impeller diameter and pump speed. All else being equal, the pump head is proportional to the square of the speed, so speed has a significant impact on the head. Sometimes, external factors may cause the pump speed to drop, which lowers the head accordingly. In that case, check the pump speed, find the reason, and address it properly.

4. Cavitation at the pump inlet
If the inlet pressure of the pump is too low and falls below the saturation pressure of the fluid, cavitation occurs. Check if the inlet pipeline is blocked, if the inlet valve is too closed, or consider raising the liquid level in the suction tank.

5. Operating point shifts toward higher flow
In general, vertical multistage centrifugal pumps have a continuously downward performance curve, with flow increasing as head decreases. During operation, if pump backpressure drops for some reason, the pump’s operating point will passively shift to a lower-head, higher-flow point, causing reduced head. This is usually due to external changes in the system rather than the pump itself. To fix it, just increase the pump backpressure, for example by slightly closing the outlet valve.

6. Impeller flow passage blockage
If the flow passages in the impeller are blocked, it affects the impeller’s performance and causes the outlet pressure to drop. In this case, the pump needs to be disassembled and cleared of debris. To prevent recurrence, if the cleanliness of the inlet fluid cannot be guaranteed, install a filter ahead of the pump.